Take this product as the test sample for hydrocarbons; Take a gas with a methane content of 0.0020% (using nitrogen as the diluent) as the reference gas, and perform the gas chromatography test according to General Rule 0521. Use a chromatographic column (0.8m) filled with glass balls × 4mm, 80 mesh); The column temperature is 110 ℃; The inlet temperature is 110 ℃; The detector temperature is 120 ℃. Measure the test sample gas and control gas, inject them into a gas chromatograph, and the peak area measured at a purification temperature of 360 ℃ is the corresponding blank value; Measure the test sample gas and control gas, inject them into a gas chromatograph, measure the peak area, and subtract the corresponding blank value to obtain the corrected peak area. Calculated using the external standard method to correct peak area, the hydrocarbon content (calculated as methane) shall not exceed 0.0020%.